Product Description
What this product is and who it is for
The Drive Med‑Aire Assure 14530 is an alternating‑pressure mattress system that also provides low air loss. It is intended for people who need pressure redistribution and microclimate control at home or in long‑term care settings. The supplied photograph shows the mattress and the external control (pump) connected.
Specifications
- Manufacturer model: Drive Med‑Aire Assure, Item #14530.
- Overall height: 8" (5" air cells over a 3" foam base). (Manufacturer specification.)
- Published footprint: approximately 80" length; published width is listed by Drive as 35"–36" depending on source; see warnings for discrepancy.
- Weight capacity (manufacturer): 350 lb.
- Control unit: compressor type, 8 L/min airflow, 10‑minute alternating cycle; visual and audible low‑pressure alarms and a mute function (manufacturer manual).
- Pressure range (manufacturer listings/manuals): published ranges vary; see warnings.
What is included
- The system as shown: alternating‑pressure mattress with quilted cover and an external control unit (pump) with tubing and quick‑release connectors.
- Manufacturer lists separate part numbers for Pump (14530P), Mattress only (14530M) and Cover (14530C); some retailers sell those components separately.
Condition and packaging
- The provided photo shows the assembled mattress and pump on a white background; no boxed packaging or factory seals are visible in the image.
- Listing is prepared as a used/open condition offer unless the seller provides evidence of factory sealing and original unopened packaging.
Usage notes
- The pump offers a static (firm) mode to help transfers and an alternating mode with a 10‑minute cycle; the manual recommends using static mode for initial inflation and transfers (manufacturer manual).
- CPR valve is provided for rapid deflation in emergencies (manufacturer specification).
- Tubing uses an EZ‑Lock/quick‑release connector for the control unit (manufacturer specification).
- Routine cleaning/disinfection instructions and environmental operating ranges are provided in the manufacturer manual; the mattress and cover should be fully dried after cleaning.
Limitations and regulatory notes
- This device is listed with HCPCS/E code references on manufacturer pages; some retailers label it as prescription/Rx only — check local regulator/insurer requirements before purchase.
- Exact published width and the number of air cells differ between Drive documentation and reseller pages; buyer should confirm the required footprint (35–36" width reported) and air‑cell count with the seller before purchase.
Warnings
- Packaging and factory seals are not shown in the supplied photo; do not assume the item is new/sealed. See 'Warnings' section in the analysis output for specification conflicts and Rx requirements.