Product Description
What this product is and who it is for
- ZOLL CPR‑D‑padz (REF 8900‑0800‑01) is a one‑piece adult defibrillation electrode assembly that provides defibrillation therapy and CPR feedback when used with compatible ZOLL defibrillators. It is intended for purchasers who need a replacement electrode set for a ZOLL AED or who maintain AED inventory.
Specifications
- Part number: 8900‑0800‑01 (manufacturer REF).
- Design: one‑piece adult electrode (both electrodes on a single sheet) suitable for patients 8 years or older or >55 lb as per ZOLL guidance.
- Shelf life: 5 years (manufacturer).
- Packaging: supplied in a multilayer foil laminate pouch; each package contains one one‑piece electrode assembly.
- Environment: operating temperature 0°C to 50°C; short‑term storage −30°C to 65°C; long‑term storage 0°C to 35°C.
- Materials: polymer hydrogel conductive gel; conductive element: tin; product not made with natural rubber latex.
- Connector: pre‑connected electrode plug designed to seat in ZOLL electrode port.
What is included
- One (1) one‑piece CPR‑D‑padz electrode assembly (pre‑connected).
- Manufacturer lists an accessory kit supplied with the product: gloves, barrier mask, scissors, razor, wet wipe and dry wipe (pack contents shown on manufacturer product details).
- The AED, batteries, and other AED accessories are not included.
Compatibility and limitations
- Stated compatible devices include ZOLL AED Pro, AED Plus, AED 3 BLS, R Series, X Series and Propaq MD (refer to the device Operator’s Guide for full compatibility notes).
- The manufacturer warns Real CPR Help (live CPR prompting/feedback) may not function when CPR‑D‑padz are used on defibrillators other than AED Plus/AED Pro; check your AED’s Operator’s Guide for CPR feedback behavior.
Condition and packaging
- New, factory‑packaged electrode sold in a sealed foil pouch. The supplied photograph shows the electrode displayed alongside a sealed pouch for illustration; actual sale is of a new, factory‑sealed package unless the listing states otherwise.
Usage notes
- Do not open until ready to use.
- Wipe the patient’s chest dry and remove excessive hair for good adhesion.
- Replace electrodes after 24 hours on skin or after a single use.
Warnings
- Do not use if the conductive gel is dry or if the pouch is damaged.
- CPR feedback and some functionality may be limited with non‑ZOLL defibrillators — see manufacturer guidance.
- This listing does not show or guarantee expiry dates on any pictured pouch; buyers should confirm expiry on receipt.
Product Videos
Custom Field
BBMProdID BBM01