Product Description
What this product is and who it is for
- Replacement disposable inner cannula intended for use with Shiley XLT (extended-length) adult tracheostomy tubes. Ideal for clinical settings or caregivers who need matched spare inner cannulae for XLT tubes.
Specifications
- Manufacturer part number: 60XLTIN.
- ISO/inner diameter (I.D.): 6.0 mm (identifies the inner cannula I.D.).
- Outer diameter (O.D.): 11.0 mm (manufacturer specification for 6.0 mm I.D. XLT inner cannula).
- Total length: 95 mm (manufacturer specification for 6.0 mm XLT inner cannula).
- Packaging: 10 disposable inner cannulae per box (10/box).
- Material / safety: 100% latex-free; single-use, supplied sterile per manufacturer.
- Compatibility: For Shiley XLT (extended-length) tracheostomy tubes only — not for non-XLT (legacy or unrelated) tube models.
How to distinguish this exact variant from adjacent variants:
- This variant is the 6.0 mm I.D. replacement inner cannula (catalog 60XLTIN). Adjacent variants use catalog numbers 50XLTIN (5.0 mm I.D.), 70XLTIN (7.0 mm I.D.) and 80XLTIN (8.0 mm I.D.). Confirm the printed catalog number or the ISO/I.D. size on the packaging before ordering.
What is included in the box
- Boxed set of 10 disposable inner cannulae (10 units per box). Nothing else (tubes, holders or other accessories are not included in the box of inner cannulae).
Condition and packaging (as evidenced / caveated)
- Units are manufacturer-supplied, factory-packaged in a retail/medical supply box (10 per box). The item is sterile and single-use per manufacturer documentation.
- Photographs provided with this listing show a retail box with branding and a single cannula displayed for reference; photos do not verify intact sterile seals or expiry dates on the lot. See warnings.
Usage notes and limitations
- Intended only for Shiley XLT extended-length tracheostomy tubes. Do not attempt to use this inner cannula with non-XLT models unless explicitly stated compatible by the tube manufacturer.
- Single-use disposable component; dispose of per facility infection-control policies after use.
Regulatory / ordering note
- This is a regulated medical device. Institutional purchasers should confirm purchasing policies; some suppliers require clinical account or prescription authorization to buy.
Warnings
- The packaging in photographs may show legacy Covidien branding; confirm the catalog number (60XLTIN) and size before use.
- Expiry dates, lot/serial numbers and sterility indicators are not visible in the listing photos — customers must not assume a specific expiry or opened/unused state from photos alone.
- Do not mix inner cannula sizes or variants — selecting the wrong I.D. will affect patient airway diameter and may require tube change by clinical staff.